Dimplex DWF1203 Manuale di Servizio

Navigare online o scaricare Manuale di Servizio per Riscaldatori e bollitori per acqua Dimplex DWF1203. Dimplex DWF1203 Service manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 0
Service Manual
Model
DWF1203
Part Number
6908490100
7400580000R00
In keeping with our policy of continuous product development, we reserve the right to make changes without notice.
© 2012 Dimplex North America Limited
Dimplex North America Limited
1367 Industrial Road
Cambridge ON Canada N1R 7G8
1-888-346-7539
www.dimplex.com
REV PCN DATE
00 - 7-AUG-12
IMPORTANT SAFETY INFORMATION: Always read this manual rst before attempting to service this replace. For your
safety, always comply with all warnings and safety instructions contained in this manual to prevent personal injury or prop-
erty damage.
Vedere la pagina 0
1 2 3 4 5 6 ... 14 15

Sommario

Pagina 1 - Service Manual

Service ManualModelDWF1203Part Number69084901007400580000R00In keeping with our policy of continuous product development, we reserve the right to make

Pagina 2 - TABLE OF CONTENTS

10 www.dimplex.comCIRCUIT BOARD REPLACEMENT REMOTE CONTROL RECEIVER or LED DRIVER BOARD Tools Required: Philips head screwdr

Pagina 3 - OPERATION

11place. (Figure 8)Inside the lower cavity, locate the Flicker Motor and 11. the Flicker Rod. The Flicker Rod can be removed by re-moving the brackets

Pagina 4 - MAINTENANCE

12 www.dimplex.comcenter of the back of the unit. (Figure 7)Lay unit on its back and remove the remaining nine (9) 7. screws

Pagina 5 - REPLACEMENT PARTS LIST

13 CAUTION: Ensure that the remote control wire antenna is placed so that it is not caught between any of the screws or sheets of metal.! NOTE: Be su

Pagina 6 - WIRING DIAGRAM

14 www.dimplex.comPROBLEM CAUSE SOLUTIONGeneralCircuit breaker trips or fuse blows when unit is turned onShort in unit wiring

Pagina 7 - REPLACEMENT

15PROBLEM CAUSE SOLUTIONHeaterHeater is not turning Off Improper operation Refer to Operation SectionDefective Heater On/Off Switch Defective Heater O

Pagina 8 - POWER CORD REPLACEMENT

2 www.dimplex.comAlways use a qualied technician or service agency to repair this replace.! NOTE: Procedures and technique

Pagina 9 - HEATER ASSEMBLY REPLACEMENT

3Remote ControlThe replace is supplied with a radio frequency remote control. This remote control has a range of approximately 50 feet (15.25 m), it

Pagina 10 - FLICKER ROD REPLACEMENT

4 www.dimplex.comMAINTENANCE WARNING: Disconnect power before attempting any maintenance or cleaning to reduce the risk of

Pagina 11 - FLICKER MOTOR REPLACEMENT

5EXPLODED PARTS DIAGRAMREPLACEMENT PARTS LISTHeater Assembly (with Cutout)1. ... 2200490800RPFront Glass2. . . . . . . . . . . . . . . . .

Pagina 12 - LED LIGHT STRIP REPLACEMENT

6 www.dimplex.comWIRING DIAGRAMP1P2

Pagina 13

7SWITCH REPLACEMENTTools Required: Philips head screwdriverFlat head screwdriverNeedle-nose pliers WARNING: If the replace was operating prior to

Pagina 14 - TROUBLESHOOTING GUIDE

8 www.dimplex.comOn either side of the rebox, remove the retaining 1. screws and carefully remove the glass assembly from th

Pagina 15 - PROBLEM CAUSE SOLUTION

9(7) screws around the outside of the end panel. (Figure 5)Lay unit on its back and remove the remaining nine (9) 6. screws from the end panel.Remove

Commenti su questo manuale