Dimplex SCxn175d Istruzioni per gli Interventi Pagina 20

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 19
Unvented hot water cylinder – SCxn…d/i, SCxn…sd/si
Page 19 of 28
ST0109 – C 05/09
WATER
5.12 Wiring schematic solar loop
The integration of the Dimplex solar SCxn cylinder is shown in Figures 11 and 12. The
wiring schematic for the solar loop is shown in Figure 13.
Figure 13 – Solar loop integration
5.13 Solar sensor installation
The Dimplex solar SCxn range cylinders allow for the installation of two sensors. The
lower sensor is required to control the solar circulation pump. The upper sensor is for
information only to indicate the actual available hot water temperature.
Two ½” sensor pockets are supplied with the pump unit. The sensor pockets are to be
used to install the sensors in the cylinders.
The location of the sensor bosses is indicated in Figure 14, also showing the methodol-
ogy of installing the sensor into the sensor pocket. A suitable sealant is to be used such
as Loctite 577.